Hi Frans,
Is it possible to up the clock frequency for my MF X-Dac V3 DSD1792 from 24.576 MHz to double and the MF X-Dac V3 will still work?
Thanks.
Ostebaronen skrev:
What is the purpose of doubling the clock frequency?
Javier skrev:
In order to use an oversampling rate of the delta-sigma (ΔΣ) modulator of 128 fS, the system clock frequency is required to be greater than 256 fS.
PS. 88.2 and 176.4KHz sampling rates are missing in the table but both are accepted.